BFBYF - 308L ELECTRODE

  • MSDS: BFBYF
  • Manufacturer: J W HARRIS CO INC
  • Product Name: 308L ELECTRODE
  • National Stock Number: 3439-00-511-9704
Product Identification

Product ID:308L ELECTRODE
MSDS Date:01/01/1987
FSC:3439
NIIN:00-511-9704
MSDS Number: BFBYF

Responsible Party
J.W.HARRIS CO,INC

Emergency Phone: 513-891-2000

Cage: 27911

Contractor
J. W. HARRIS CO., INC.
CINCINNATI, OH 45242-4110 US

Telephone: 513-891-2000

Cage: 27911

Ingredients

IRON OXIDE

CAS: 1309-37-1

RTECS: NO7400000

Fraction By Weight: BAL

OSHA PEL 10 MG/M3 (FE)

ACGIH TLV: 5 MG/M3(FE),B2; 9293


CHROMIUM (SARA III)

CAS: 7440-47-3

RTECS: GB4200000

Fraction By Weight: 20%

OSHA PEL 1 MG/M3

ACGIH TLV: 0.5 MG/M3; 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


NICKEL (SARA III)

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 10%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9192


MANAGANESE(CAS#7439-96-5)(1-2.5%)

Fraction By Weight: 2%

ACGIH TLV: 5MG/CUM


MOLYBDENUM

CAS: 7439-98-7

RTECS: QA4680000

Fraction By Weight: 2%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3; 9293

Hazards

Effects of Overexposure:DISCOMFORT.DIZZINESS.NAUSEA,PULMONARY
IRRITATION.NICKEL & CHROMIUM:POSSIBLE CARCINOGENS.

First Aid

First Aid:REMOVE FROM DUST OR FUME EXPOSURE. IF BREATHING HAS
STOPPED,PERFORM ARTIFICIAL RESPIRATION. SUMMON MEDICAL AID
IMMEDIATELY.

Fire Fighting

Extinguishing Media:NONE
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:WELDING ARC.OPEN FLAME & SPARKS CAN
IGNITE COMBUSTIBLES.

Accidental Release

Spill Release Procedures:NORMAL PROCEDURE.

Handling

Handling and Storage Precautions:NONE

Exposure Controls

Respiratory Protection:FUME RESPIRATOR.
Ventilation:USE ENOUGH VENTILATION.
Protective Gloves:YES
Eye Protection:GOGGLES
Other Protective Equipment:FACE SHIELD.
Supplemental Safety and Health
MSDS DATED 11-85.

Chemical Properties

HCC:N1
Appearance and Odor:SOLID WIRE OR ROD.RODS ARE COATED W/FLUX.

Stability

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:DIFFICULT TO DETERMINE. VARIES
GREATLY.

Disposal

Waste Disposal Methods:MFG DID NOT SPECIFY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.